Product

FlashLink VU Universal Protein Data Logger

FlashLink® VU Protein In-Transit Logger, Model 20862: This single-use in-transit data logger is accepted by most receivers and is the ideal cold chain management tool for tracking temperature during transportation of protein products. It can be used on all outbound loads, so suppliers are able to consolidate their temperature recorders to one model. Using the FlashLink VU Protein In-Transit Logger means there is no need to stock various brands in the shipping office, making inventory management easy, and eliminating the problem of running out of any one particular type of logger for a specific receiver.

This logger is designed specifically for use on shipments of protein products, with preconfigured alarm settings to alert receivers with a flashing red LED when temperature during transit has gone above 36°F/2°C or below 28°F/-2°C. Mounted on a bright green shipping card, it is easy for receivers to locate the logger upon arrival, which helps to expedite the process of downloading trip information. Our patented Shadow Log® feature guarantees data, even if the shipper forgets to start the unit. The loggers are downloaded using free FlashPDF software, and reports are saved in PDF format to email and archive for record keeping, traceability and to help comply with HACCP and FSMA (Food Safety Modernization Act) requirements. An optional CT Graphics Printer provides a paper strip chart when PCs are not available on the receiving dock.

FlashLink VU VU Universal Produce Data Logger

DeltaTrak’s FlashLink® VU Universal Produce Data Logger is accepted by most receivers and is the ideal cold chain management tool for tracking temperature during transportation of fresh produce. It can be used on all outbound loads, so suppliers are able to consolidate their temperature recorders to one model, with the FlashLink VU Universal Produce Data Logger. There is no need to stock various logger brands in the shipping office, making inventory management easy, and eliminating the problem of running out of any one particular brand for a specific receiver.

The FlashLink VU Universal Produce Data Logger is designed specifically for use on produce shipments, with preconfigured alarm settings to alert receivers with a flashing red icon on the LCD when temperature during transit has gone either above 41°F/5°C or below 33°F/0.5°C. It is also factory programmed with delay start and an alarm delay of 60 minutes. Mounted on a bright green shipping card, it is easy for receivers to locate the logger upon arrival, which helps to expedite the process of downloading trip information. Our patented Shadow Log® feature guarantees data, even if the shipper forgets to start the unit. The loggers are downloaded using free FlashPDF software, and reports are saved in PDF format to email and archive for record keeping and traceability. An optional CT Graphics Printer can provide a paper strip chart when PCs are not available on the receiving dock.

FlashLink VU Data Logger

The new FlashLink® VU In-Transit Data Logger is the ideal device for recording storage and transport conditions of temperature-sensitive products. This in-transit temperature data logger has a large easy to read LCD display that provides immediate temperature status information and trip statistics including upper and lower temperature limits, cumulative duration of any temperature excursions, highest temperature, lowest temperature, and average temperature.

The FlashLink® VU data logger allows for access to temperature history data without having to stop the unit or download the data. DeltaTrak's patented Shadow Log® feature guarantees temperature history data even if the operator fails to start the data logger. The single-use FlashLink® VU temperature data logger is packaged in a highly visible yellow sleeve with easy to follow instructions and helps the receiver locate the data logger very quickly.

FlashLink VU In-Transit Data Logger

DeltaTrak’s FlashLink® VU In-Transit Produce Data Logger is specifically designed for use in the storage and transport of temperature-sensitive produce. The in-transit temperature data loggers are pre-programmed with high/low alarm settings applicable to produce (41°F/33°F). Customers shipping produce can now use this one data logger for their shipments to multiple produce resellers. Packaged in a highly visible yellow sleeve, the data loggers are easily identified in a load of product and include easy-to-follow instructions.

The large, easy to read LCD display provides immediate temperature status information and trip statistics including upper and lower temperature limits, cumulative duration of any temperature excursions, highest temperature, lowest temperature, and average temperature. DeltaTrak's patented Shadow Log® feature guarantees temperature history data even if the operator fails to start the data logger.

Model 20862

FlashLink® VU Protein In-Transit Logger

Model 20862

FlashLink VU Universal Protein Data Logger

This single-use in-transit data logger is accepted by most receivers and is the ideal cold chain management tool for tracking temperature during transportation of protein products. It can be used on all outbound loads, so suppliers are able to consolidate their temperature recorders to one model. Using the FlashLink VU Protein In-Transit Logger means there is no need to stock various brands in the shipping office, making inventory management easy, and eliminating the problem of running out of any one particular type of logger for a specific receiver.

This logger is designed specifically for use on shipments of protein products, with preconfigured alarm settings to alert receivers with a flashing red LED when temperature during transit has gone above 36°F/2°C or below 28°F/-2°C. Mounted on a bright green shipping card, it is easy for receivers to locate the logger upon arrival, which helps to expedite the process of downloading trip information. Our patented Shadow Log® feature guarantees data, even if the shipper forgets to start the unit. The loggers are downloaded using free FlashPDF software, and reports are saved in PDF format to email and archive for record keeping, traceability and to help comply with HACCP and FSMA (Food Safety Modernization Act) requirements. An optional CT Graphics Printer provides a paper strip chart when PCs are not available on the receiving dock.

  • Accepted by most receivers
  • Consolidate logger inventory with one brand for all shipments
  • High/Low alarms programmed for produce
  • Mounted on high-visibility locator card
  • Trip history statistics available on LCD
  • Patented Shadow Log feature guarantees data even if the operator fails to start the unit
  • Download data to PC as secure PDF report or print chart using CT Graphics printer
Download FlashLink® VU Universal Protein Data Logger Spec Sheet  FlashLink VU Protein In-Transit Logger

Specifications

FlashLink® VU Protein In-Transit Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 90001:2008 registered quality management system
Patent No. 6,088, 514
Recording Period 15 Days
Logging Interval 6 min
Measurement Range -40°F to 122°F (-40°C to 50°C)
Temperature Resolution 0.1°F/°C
Temperature Accuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);
±2.0°F above 77°F (±1.0°C above 25°C)
±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 3823 points
Data Download Time 5 seconds typical for 3823 points
Alarms/Settings High 36° F (2°C), Low 28° F (-2°C)
Battery Coin Cell Lithium Battery
Logger Dimensions 1.962" x 3.423" x .575" (50mm x 87mm x 15mm)
Casing ABS plastic
Logger Weight 1.6 oz. (45.36 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, NIST traceable, ROHS Compliant
Display °F Scale on LCD, Red LED Alarm
IP Rating IP56
Storage Conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
Min. System Requirements Windows PC with current operating system, FlashPDF software, Adobe Reader
Download Requirements 8-Pin to USB Adapter
Download FlashLink® VU Produce In-Transit Logger Spec Sheet  FlashLink VU Produce In-Transit Logger

Packaging

Each FlashLink VU Protein Logger is mounted on a bright green shipping card. This makes it easy to find when a load arrives and enables receivers to download the trip report immediately. The card has printed instructions in English and Spanish, for shippers to start the logger and receivers to download the unit. A diagram identifies and describes the various icons that can be displayed on the LCD.

Packaging

Software

FlashPDF

FlashPDF

FlashPDF is a simple program used to create a locked PDF file with data downloaded from any FlashLink data logger. Once installed on a Windows PC, the program runs automatically when a logger is connected via the USB adapter. The PDF is then created, saved, and displayed on screen automatically. These PDF files can easily be archived and emailed.

More information on FlashPDF Software

Model 20879-20889

FlashLink® VU Universal Produce Data Logger

Model 20879-20889

FlashLink VU VU Universal Produce Data Logger

This data logger is accepted by most receivers and is the ideal cold chain management tool for tracking temperature during transportation of fresh produce. It can be used on all outbound loads, so suppliers are able to consolidate their temperature recorders to one model, with the FlashLink VU Universal Produce Data Logger. There is no need to stock various logger brands in the shipping office, making inventory management easy, and eliminating the problem of running out of any one particular brand for a specific receiver.

The FlashLink VU Universal Produce Data Logger is designed specifically for use on produce shipments, with preconfigured alarm settings to alert receivers with a flashing red icon on the LCD when temperature during transit has gone either above 41°F/5°C or below 33°F/0.5°C. It is also factory programmed with delay start and an alarm delay of 60 minutes. Mounted on a bright green shipping card, it is easy for receivers to locate the logger upon arrival, which helps to expedite the process of downloading trip information. Our patented Shadow Log® feature guarantees data, even if the shipper forgets to start the unit. The loggers are downloaded using free FlashPDF software, and reports are saved in PDF format to email and archive for record keeping and traceability. An optional CT Graphics Printer can provide a paper strip chart when PCs are not available on the receiving dock.

ModelsHigh AlarmLow AlarmAlarm DelayDelay Start
20879 41ºF (5ºC) 33ºF (0.6ºC) 60 min. 60 min.
20889 None None None 60 min.
  • Accepted by most receivers
  • Consolidate logger inventory with one brand for all shipments
  • High/Low alarms programmed for produce
  • Mounted on high-visibility locator card
  • Trip history statistics available on LCD
  • Patented Shadow Log feature guarantees data even if the operator fails to start the unit
  • Download data to PC as secure PDF report or print chart using CT Graphics printer
Download FlashLink® VU Produce In-Transit Logger Spec Sheet  FlashLink VU Produce In-Transit Logger

Specifications

FlashLink® VU Produce In-Transit Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 90001:2008 registered quality management system
Patent No. 6,088, 514
Recording Period 15 Days
Logging Interval 5 min, 40 sec
Measurement Range -40°F to 122°F (-40°C to 50°C)
Temperature Resolution 0.1°F/°C
Temperature Accuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);
±2.0°F above 77°F (±1.0°C above 25°C)
±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 3823 points
Data Download Time 5 seconds typical for 3823 points
Alarms/Settings High 41° F (5°C), Low 33° F (0.5°C)
Delay Start 60 min, Alarm Delay 60 min
Battery Coin Cell Lithium Battery
Logger Dimensions 1.962" x 3.423" x .575" (50mm x 87mm x 15mm)
Casing ABS plastic
Logger Weight 1.6 oz. (45.36 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, NIST traceable, ROHS Compliant
Display °F Scale on LCD, Red LED Alarm
IP Rating IP56
Storage Conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
System Requirements Windows PC with current operating system, Adobe Reader, FlashPDF Software
Download Requirements 8-Pin to USB Adapter
Download FlashLink® VU Produce In-Transit Logger Spec Sheet  FlashLink VU Produce In-Transit Logger

Packaging

Each FlashLink VU Produce Logger is mounted on a bright green shipping card. This makes it easy to find when a load arrives and enables receivers to download the trip report immediately. The card has printed instructions in English and Spanish, for shippers to start the logger and receivers to download the unit. A diagram identifies and describes the various icons that can be displayed on the LCD.

Packaging

Software

FlashPDF

FlashPDF

FlashPDF is a simple program used to create a locked PDF file with data downloaded from any FlashLink data logger. Once installed on a Windows PC, the program runs automatically when a logger is connected via the USB adapter. The PDF is then created, saved, and displayed on screen automatically. These PDF files can easily be archived and emailed.

More information on FlashPDF Software

Model 20741-20744

FlashLink® VU In-Transit Logger, Model 20741-20748

The new FlashLink® VU data logger is the ideal device for recording storage and transport conditions of temperature-sensitive products. This in-transit temperature data logger has a large easy to read LCD display that provides immediate temperature status information and trip statistics including upper and lower temperature limits, cumulative duration of any temperature excursions, highest temperature, lowest temperature, and average temperature.

FlashLink VU In-Transit Data Logger

Overview

The FlashLink® VU data logger allows for access to temperature history data without having to stop the unit or download the data. DeltaTrak's patented Shadow Log® feature guarantees temperature history data even if the operator fails to start the data logger. The single-use FlashLink® VU temperature data logger is packaged in a highly visible yellow sleeve with easy to follow instructions and helps the receiver locate the data logger very quickly.

Models 5-Day 15-Day 45-Day 75-Day
Logging
Interval
1 min
54 sec
5 min
40 sec
16 min
58 sec
28 min
16 sec
°F Models 20741 20742 20743 20744
°C Models 20745 20746 20747 20748

Applications: Ideal device for documenting storage and transport condition of temperature-sensitive products.

  • Large, easy to read LCD display
  • Trip history statistics available on LCD
  • Patented Shadow Log feature guarantees data even if the operator fails to start the unit, single-use
  • Print data using Graphics Printer, FlashPDF software or download to PC
  • NIST traceable and CE Mark
  • IP56 water-resistant rating

Specifications

FlashLink® VU In-Transit Data Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 9000 registered quality management system
Measurement Range -40°F to 150°F (-40°C to 65°C)
Temperature Resolution 0.1°F/°C
Accuracy ±1.0°F from 14°F to 77°F (±.5°C from -10°C to 25°C);
±2.0°F above 77°F (±1.0°C above 25°C)
±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 3824 points
Data Download Time 5 seconds typical for 3800 points
Factory Programmable High & Low levels over entire range, displayed on LCD
Battery (CR2032) 3V Lithium/18 months
Dimensions 1.962" x 3.423" x .575" (50mm x 87mm x 15mm)
Casing ABS plastic
Weight 1.6 oz. (45.36 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, NIST traceable, ROHS Compliant
Display LCD, Red LED Alarm
Waterproof Rating IP56
Storage Conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
System Requirements Windows PC with current operating system, Adobe Reader, FlashPDF software
Download Requirements 8-Pin to USB adapter
Download FlashLink® VU In-Transit Data Logger Spec Sheet  FlashLink VU In-Transit Data Logger

Packaging

High visibility shipping sleeve.

Packaging

Software

FlashPDF

FlashPDF

FlashPDF is a simple program used to create a locked PDF file with data downloaded from any FlashLink data logger. Once installed on a Windows PC, the program runs automatically when a logger is connected via the USB adapter. The PDF is then created, saved, and displayed on screen automatically. These PDF files can easily be archived and emailed.

More information on FlashPDF Software

Accessories

Model 20719 - FlashLink 8 pin USB Adapter Kit

Model 20719: FlashLink 8 Pin to USB High Speed Adapter Kit

  • Eight pin to USB adapter
  • USB extension cable included

Download FlashLink 8 Pin to USB High Speed Adapter Kit Spec Sheet

Model 20881-20892

FlashLink® VU In-Transit Produce Data Logger

FlashLink VU In-Transit Produce Data Logger
FlashLink® VU with high visibility locator card
Applications: Ideal device for documenting storage and transport condition of temperature-sensitive products.
  • Single-use
  • Large, easy to read LCD display
  • Trip history statistics available on LCD
  • Patented Shadow Log feature guarantees data even if the operator fails to start the unit
  • Print data using Graphics Printer, FlashPDF software or download to PC
  • NIST traceable and CE Mark
  • IP56 water-resistant rating
FlashLink® VU In-Transit Produce Data Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 9000 registered quality management system
Measurement Range -40°F to 150°F (-40°C to 65°C)
Temperature Resolution 0.1°F/°C
Accuracy ±1.0°F from 14°F to 77°F (±.5°C from -10°C to 25°C);
±2.0°F above 77°F (±1.0°C above 25°C)
±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 3824 points
Data Download Time 5 seconds typical for 3800 points
Alarm Levels High 41° F (5°C), Low 33° F (.05°C)
Battery Lithium Coin Cell
Dimensions 1.962" x 3.423" x .575" (50mm x 87mm x 15mm)
Casing ABS plastic
Weight 1.6 oz. (45.36 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, NIST traceable, ROHS Compliant
Display LCD, Red LED Alarm
IP Rating IP56
Storage Conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
Min. System Requirements Windows PC with current operating system
Software Requirements FlashPDF software package #20163
To download a pdf version of this specification sheet please click here FlashLink VU In-Transit Produce Data Logger